Cookie Consent by Free Privacy Policy website

Special application PL750


Download PDF

10 kOhm Linear Potentiometer. Ideal for application as plastic injection presses such as vertical presses and many other material processing machines.


Zoom Click to enlarge image

Special application PL750 Special application PL750 Schema Special application PL750 Montaggio

Technical Specifications

Linearity± 0,05%
Reapeatability< 0.01 mm
Operating temperature-20 / +80°C (-4 / +176°F)
Protection classIP 65
Dimensions (mm)33 mm x 33 mm
Storage temperature- 30 °C / + 90 °C (-22 °F / 194 °F)
Measurement stroke750 mm (29.52 in)
ResolutionInfinite
Resistance10 kΩ
Resistance tolerance± 20%
Load Resistance100 kΩ min
Recommended cursor current< 1 µA
Max applied voltageMaximum 28 V dc
Electrical connections4 pin connector
Displacement speed< 5 ms
Mechanical life100 million cycles
Case materialAnodized aluminium
Rod materialStainless steel
Rod diameterØ6 mm
Mechanical fixingVaVariable bracketsriable brackets
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

TypeLINEAR POTENTIOMETER
Lengthnd (body lead cell not connected shield)
Brown+ IN
Blue- IN
YellowOUTPUT
Connections  Special application PL750

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means